Heavy Mould Damage Procedure
Safety
Our first concern to address to completing the job was ensuring the safety of all trades and people attending the site. We installed appropriate containment and air filtration devices (AFD) under negative pressure to ensure both safety and secondary damage. Once complete an Electrical make-safe was conducted to the house and solar panels.
Contents
A large concern was mitigating further damage to the insureds contents. On first day, contents items such as furniture or any other porous items that were at risk were identified and isolated in a clean environment. We then installed an AFD in that area to ensure safety to the items. During the below remediation, all mould affected contents were document and assessed.
Remediation
All affected non structural building materials in the lower level were then removed by technicians wearing electronic resperators and full set of PPE. The building material was then disposed off site. After these were removed, mould remediation to exposed structural building elements began. This includes HEPA vacuuming to all affected surfaces, abrasive scrub to all timber joists, beams, & stud frames, wet wipe and treatment to all affected areas, and pressure clean to concrete subfloor and tiled areas. Once the primary remdiation had been completed, the area was then treat with a H202 vaporisation as a knock down treatment. All exposed timber was then excapsulated with ecapsulation paint.
Testing
A third party hygienist was then engaged to give the clearance testing.